This document describes the connection diagrams on the inverters that we use.
+
This document describes the connection diagrams between the spindle and inverter.
  
 
== TECO FM100 and Motortronics Inverters ==
 
== TECO FM100 and Motortronics Inverters ==
Line 44: Line 44:
  
 
Trip Relay (2) SYN- (10) White
 
Trip Relay (2) SYN- (10) White
 +
 
Trip Relay (1) SYN+ (11) Green
 
Trip Relay (1) SYN+ (11) Green
  
  
 
[[Category:Electronics]]
 
[[Category:Electronics]]

Revision as of 08:22, 21 October 2010

This document describes the connection diagrams between the spindle and inverter.

TECO FM100 and Motortronics Inverters

Pin Wire Color Inverter Terminal
1 Black COM (5)
2 Green SYN+ (11)
3 Orange SP1 (6)
4 Yellow SP2 (7)
5 Red FWD (3)
6 White SYN- (10)
7 NC
8 Blue SP3 (8)

The inverter also requires the following jumper wires:

Trip Relay (2) SYN- (10) White

Trip Relay (1) SYN+ (11) Green