From TechnoDocs
(Created page with "One of the following errors are received: File:Axis_lost_pulses.jpg File:Axis_lost_pulses_2.jpg This is a very critical error that can result in a lot of problems: * ...") |
|||
Line 14: | Line 14: | ||
The causes of this problem are (in order of probability): | The causes of this problem are (in order of probability): | ||
− | * Dust on the encoder (if the environment is dusty) | + | * [[Encoder damage|Dust on the encoder]] (if the environment is dusty) |
− | * Broken encoder | + | * [[Encoder damage|Broken encoder]] |
− | * Bent Control Cable pin or damaged cable (LC Plus or Premium electronics only, this is NEVER caused by a bent pin on an LC / LP controller) | + | * [[Verify control cable|Bent Control Cable pin or damaged cable]] (LC Plus or Premium electronics only, this is NEVER caused by a bent pin on an LC / LP controller) |
* Nicked or damaged encoder cable wire | * Nicked or damaged encoder cable wire |
Revision as of 11:00, 2 September 2011
One of the following errors are received:
This is a very critical error that can result in a lot of problems:
- Machine drift
- Runaway conditions
- Location problems
- Cut quality issues
The causes of this problem are (in order of probability):
- Dust on the encoder (if the environment is dusty)
- Broken encoder
- Bent Control Cable pin or damaged cable (LC Plus or Premium electronics only, this is NEVER caused by a bent pin on an LC / LP controller)
- Nicked or damaged encoder cable wire