Revision as of 06:44, 27 September 2010
An inverter is an electrical device that converts direct current (DC) to alternating current (AC). It may be single phase or 3 phase, and powers the machine’s systems and motors. It is so named because early mechanical AC to DC converters were modified and made to work in reverse, and thus were "inverted", to convert DC to AC.
Contents
Inverter Basics
Inverters usually need to be programmed with values obtained from the name plate on the spindle (get pic) of the machine into which the inverter is to be installed.
Shown here are 2 inverters, an Altivar 31 (note that it says "Altivar 31" below the blue Telemechanique Logo). The second inverter is a Teco FM100, which we no longer use though you may still encounter some. Important considerations in replacing inverters are:
- Phase (single phase or 3 phase?)
- ATC (does machine have an automatic tool changer?)
- Horsepower
- Voltage
- Amperage
To test spindle, short the screws marked " +24V " and " LI1 " , the small red and black wires above
To change the direction of spindle rotation, swap any 2 of the large Red, Black, or White wires at lower left EXCLUDING GREEN, i.e. swap red & black, or, red and white, or black & white
Part Numbers for Telemechanique Altivar 31
Electronics Part Number
- 05HP/230v = H24Z40-IV5HP230V
- 10HP/230v = H24Z40-IV10HP230
- 15HP/230v = H24Z40-IV15HP230
- 05HP/240v = ????
- 10HP/240v = ????
- 05HP Inverter Conduit Box = H24M10-VW3A31815
- 10HP Inverter Conduit Box = H24M10-VW3A31816
Programming Inverters
Required Tools
- Serial-to-RJ45 cable
- PowerSuite application
- Power leads
Quick Method
- Connect serial-to-RJ45 cable
- Start PowerSuite
- Click " i " button
- My Configurations
- Altivar Drives
- ATV31
- Altivar Drives
- My Configurations
- Find your inverter on the list
- Right-click + Download
- Alt-F at warning
- Click OK
If that method failed, try the longer method.
Alternate (Long) method
- Follow above steps
- My Device
- Click "Connect the Device" button on toolbar
- Ingnore warning
- Explorer menu:
- Motor Control
- Motor Characteristics
- Input values from Spindle plaque
- Adjustments
- Accel / Decel
- Accel should be 2 or more. this is the acceleration rate.
- Decel should be 0.5 This is set to a very low value because adaptive deceleration is used. You may try increasing the value of this. I would probably not use a value greater than 3.0. The larger the value, the longer it will take for the spindle to stop.
- Frequency range
- TFR (first)
- HSP = 300 - This is the maximum frequency.
- LSP = 100
- ITH = set this to the current on the nameplate
- Thermal Protection - use Amperage value from spindle plaque
- Optimization
- Set voltage boost = 0
- UFT = Constant
- Accel / Decel
- Application Functions
- Preset speed values
- SP2
- 100
- 133
- 166 etc.
- SP2
- Preset speed values
- Motor Control
Programming thru Inverter Funtion Buttons
The Inverter's programming can be adjusted by the user via the function buttons on the inverter itself. Please contact Technical Support for help with these functionalities.
- Save Configurations:
- drC menu > SCS > Str 1