From TechnoDocs
(Created page with "One of the following errors are received: File:Axis_lost_pulses.jpg File:Axis_lost_pulses_2.jpg This is a very critical error that can result in a lot of problems: * ...") |
|||
(3 intermediate revisions by one other user not shown) | |||
Line 4: | Line 4: | ||
[[File:Axis_lost_pulses_2.jpg]] | [[File:Axis_lost_pulses_2.jpg]] | ||
+ | |||
+ | The error code associated with this problem is: 04052010. | ||
This is a very critical error that can result in a lot of problems: | This is a very critical error that can result in a lot of problems: | ||
Line 14: | Line 16: | ||
The causes of this problem are (in order of probability): | The causes of this problem are (in order of probability): | ||
− | * Dust on the encoder (if the environment is dusty) | + | * [[Encoder damage|Broken encoder / Dust on the encoder]] (if the environment is dusty) |
− | * | + | * [[Verify control cable|Bent Control Cable pin or damaged cable]] (LC Plus or Premium electronics only, this is NEVER caused by a bent pin on an LC / LP controller) |
− | + | ||
* Nicked or damaged encoder cable wire | * Nicked or damaged encoder cable wire | ||
+ | |||
+ | Still not sure what is going on here? Read: [[About drift issues]] |
Latest revision as of 13:58, 2 January 2013
One of the following errors are received:
The error code associated with this problem is: 04052010.
This is a very critical error that can result in a lot of problems:
- Machine drift
- Runaway conditions
- Location problems
- Cut quality issues
The causes of this problem are (in order of probability):
- Broken encoder / Dust on the encoder (if the environment is dusty)
- Bent Control Cable pin or damaged cable (LC Plus or Premium electronics only, this is NEVER caused by a bent pin on an LC / LP controller)
- Nicked or damaged encoder cable wire
Still not sure what is going on here? Read: About drift issues