From TechnoDocs
Jump to: navigation, search
(Created page with "The toolchanger sensors detect the state the toolchanger is in so safe toolchanges can be performed. If the sensors fail or are misaligned, the [[TC hover pickup|toolchanger wil...")
 
Line 1: Line 1:
 
The toolchanger sensors detect the state the toolchanger is in so safe toolchanges can be performed.
 
The toolchanger sensors detect the state the toolchanger is in so safe toolchanges can be performed.
  
If the sensors fail or are misaligned, the [[TC hover pickup|toolchanger will freeze]].  
+
If the sensors fail or are misaligned, the [[TC Hover Pickup|toolchanger will freeze]].  
  
 
To test the sensors, first, [[Finding_your_spindle|determine which spindle you have]]
 
To test the sensors, first, [[Finding_your_spindle|determine which spindle you have]]

Revision as of 13:43, 6 September 2011

The toolchanger sensors detect the state the toolchanger is in so safe toolchanges can be performed.

If the sensors fail or are misaligned, the toolchanger will freeze.

To test the sensors, first, determine which spindle you have

HSD (Common on new machines) toolchanger sensor testing:

  • Remove air pressure from the machine
  • Remove the two air hoses that run into the spindle
  • Remove the 4 sensor cover screws

HSD sensors.jpg

S1 is the sensor for Chuck Closed S2 is the sensor for Chuck Open S3 is the sensor for spindle running

Unscrew the sensor clamp, remove the sensor and test it in Setup->diagnostics by putting a piece of steel up to the tip and verifying response.

If there is no response on only one sensor and all other sensors work properly, the sensor likely needs to be replaced. Contact HSD USA to obtain a replacement.

If the sensor checks out properly in diagnostics, it is probably just misaligned in the housing.

  • Notice how the sensor body is not concentric with the holder body. As you rotate the sensor in the spindle, the position of the sensor will change.
  • While watching diagnostics, rotate the sensor until the proper response is obtained, then tighten down the sensor.

Note that the spindle must be in the proper state (chuck open/closed) for the sensor to properly sense the state. This means that if you are testing the chuck closed sensor, the chuck must be closed and there must be a tool in the chuck or the sensor will never trip, no matter how good it is or where it is located.


Columbo (Less common on new machines) toolchanger sensor testing:

  • Lock out power from the spindle, leave the machine enabled.
  • Remove the 2 or 4 bolts from the top face (facing the sky) of the spindle. This exposes the chuck sensors.
  • Exercise the chuck to see how the mushroom head moves upwards and downwards and trips the sensors.
  • The top sensor is for chuck fully closed
  • The bottom sensor is for chuck fully open
  • If the top sensor (closed) seems too high, there is possibly dust/other obstructions in the spindle. It should be cleaned -- moving the sensor is not an acceptable repair in this situation.

Touch steel to the sensor and verify it responds in Setup->diagnostics.

If there is no response on only one sensor and all other sensors work properly, the sensor likely needs to be replaced. Contact PDS Columbo to obtain a replacement.