This document describes the connection diagrams between the spindle and inverter.

TECO FM100 and Motortronics Inverters

Pin Wire Color Inverter Terminal
1 Black COM (5)
2 Green SYN+ (11)
3 Orange SP1 (6)
4 Yellow SP2 (7)
5 Red FWD (3)
6 White SYN- (10)
7 NC
8 Blue SP3 (8)

The inverter also requires the following jumper wires:

Trip Relay (2) SYN- (10) White

Trip Relay (1) SYN+ (11) Green