One of the following errors are received:

Axis lost pulses.jpg

Axis lost pulses 2.jpg

This is a very critical error that can result in a lot of problems:

  • Machine drift
  • Runaway conditions
  • Location problems
  • Cut quality issues

The causes of this problem are (in order of probability):

  • Dust on the encoder (if the environment is dusty)
  • Broken encoder
  • Bent Control Cable pin or damaged cable (LC Plus or Premium electronics only, this is NEVER caused by a bent pin on an LC / LP controller)