From TechnoDocs
Jump to: navigation, search
(Programming thru Inverter Funtion Buttons)
(Alternate (Long) method)
Line 71: Line 71:
 
## Adjustments
 
## Adjustments
 
### Accel / Decel
 
### Accel / Decel
#### Accel should be ''' 2 ''' or more
+
#### Accel should be ''' 2 ''' or more. this is the acceleration rate.
#### Decel should be ''' 0.5 '''
+
#### Decel should be ''' 0.5 ''' This is set to a very low value because adaptive deceleration is used. You may try increasing the value of this. I would probably not use a value greater than 3.0. The larger the value, the longer it will take for the spindle to stop.
 
### Frequency range
 
### Frequency range
 
#### TFR (first)
 
#### TFR (first)
#### HSP = 300
+
#### HSP = 300 - This is the maximum frequency.
 
#### LSP = 100
 
#### LSP = 100
 +
#### ITH = set this t the current on the nameplate
 
### Thermal Protection - use Amperage value from spindle plaque
 
### Thermal Protection - use Amperage value from spindle plaque
 
### Optimization
 
### Optimization

Revision as of 06:44, 27 September 2010

An inverter is an electrical device that converts direct current (DC) to alternating current (AC). It may be single phase or 3 phase, and powers the machine’s systems and motors. It is so named because early mechanical AC to DC converters were modified and made to work in reverse, and thus were "inverted", to convert DC to AC.

Inverter Basics

Inverters usually need to be programmed with values obtained from the name plate on the spindle (get pic) of the machine into which the inverter is to be installed.

Shown here are 2 inverters, an Altivar 31 (note that it says "Altivar 31" below the blue Telemechanique Logo). The second inverter is a Teco FM100, which we no longer use though you may still encounter some. Important considerations in replacing inverters are:

  • Phase (single phase or 3 phase?)
  • ATC (does machine have an automatic tool changer?)
  • Horsepower
  • Voltage
  • Amperage


Altivar31.jpg

Inverter wiring.jpg

To test spindle, short the screws marked " +24V " and " LI1 " , the small red and black wires above

To change the direction of spindle rotation, swap any 2 of the large Red, Black, or White wires at lower left EXCLUDING GREEN, i.e. swap red & black, or, red and white, or black & white

12 2tecoinvert.jpg


Part Numbers for Telemechanique Altivar 31

Electronics Part Number

  • 05HP/230v = H24Z40-IV5HP230V
  • 10HP/230v = H24Z40-IV10HP230
  • 15HP/230v = H24Z40-IV15HP230
  • 05HP/240v = ????
  • 10HP/240v = ????
  • 05HP Inverter Conduit Box = H24M10-VW3A31815
  • 10HP Inverter Conduit Box = H24M10-VW3A31816

Programming Inverters

Required Tools

  • Serial-to-RJ45 cable
  • PowerSuite application
  • Power leads

Quick Method

  1. Connect serial-to-RJ45 cable
  2. Start PowerSuite
  3. Click " i " button
    1. My Configurations
      1. Altivar Drives
        1. ATV31
  4. Find your inverter on the list
    1. Right-click + Download
    2. Alt-F at warning
    3. Click OK

If that method failed, try the longer method.

Alternate (Long) method

  1. Follow above steps
  2. My Device
  3. Click "Connect the Device" button on toolbar
    1. Ingnore warning
  4. Explorer menu:
    1. Motor Control
      1. Motor Characteristics
      2. Input values from Spindle plaque
    2. Adjustments
      1. Accel / Decel
        1. Accel should be 2 or more. this is the acceleration rate.
        2. Decel should be 0.5 This is set to a very low value because adaptive deceleration is used. You may try increasing the value of this. I would probably not use a value greater than 3.0. The larger the value, the longer it will take for the spindle to stop.
      2. Frequency range
        1. TFR (first)
        2. HSP = 300 - This is the maximum frequency.
        3. LSP = 100
        4. ITH = set this t the current on the nameplate
      3. Thermal Protection - use Amperage value from spindle plaque
      4. Optimization
        1. Set voltage boost = 0
        2. UFT = Constant
    3. Application Functions
      1. Preset speed values
        1. SP2
          1. 100
          2. 133
          3. 166 etc.

Programming thru Inverter Funtion Buttons

The Inverter's programming can be adjusted by the user via the function buttons on the inverter itself. Please contact Technical Support for help with these functionalities.

Save Configurations:
drC menu > SCS > Str 1