- 13:24, 6 September 2011 (diff | hist) . . (+164) . . N Stored Offsets (Created page with "Offsets are used to remember spots on the machine between runs. They are located in * Setup * Offsets Offsets are represented as distances from the home switches.") (current)
- 13:22, 6 September 2011 (diff | hist) . . (-669) . . Limit switch (→Troubleshooting) (current)
- 13:20, 6 September 2011 (diff | hist) . . (+13) . . Electronics (→Sensors & Switches) (current)
- 13:20, 6 September 2011 (diff | hist) . . (0) . . Electronics (→Computer Card)
- 13:19, 6 September 2011 (diff | hist) . . (0) . . Estop noblink (current)
- 13:17, 6 September 2011 (diff | hist) . . (+15) . . Electronics (→Computer Card)
- 13:16, 6 September 2011 (diff | hist) . . (-2) . . Install a motor (current)
- 13:14, 6 September 2011 (diff | hist) . . (-25) . . Home switch repeatability error (current)
- 13:13, 6 September 2011 (diff | hist) . . (+10) . . Home switch repeatability error
- 13:09, 6 September 2011 (diff | hist) . . (+473) . . N Power receptacle (Created page with "The power receptacle is located at the back of the box. File:Recept.jpg It will have the power cable running into it. To check the fuses: Lock out power On receptacl...") (current)
- 13:09, 6 September 2011 (diff | hist) . . (+15) . . N File:Recept.jpg (fuse receptacle) (current)
- 12:56, 6 September 2011 (diff | hist) . . (0) . . Home switch repeatability error
- 12:56, 6 September 2011 (diff | hist) . . (+13) . . Estop no ready light (→Solution) (current)
- 12:53, 6 September 2011 (diff | hist) . . (0) . . SSB mode (current)
- 12:50, 6 September 2011 (diff | hist) . . (+32) . . Change home direction (current)
- 12:50, 6 September 2011 (diff | hist) . . (+34) . . Home switch repeatability error
- 12:48, 6 September 2011 (diff | hist) . . (+680) . . N Disable the network (Created page with "On older single-processor computers or computers with demanding network applications or network devices (wifi is a good example), the network can interfere with proper operation ...") (current)
- 12:45, 6 September 2011 (diff | hist) . . (+536) . . N Chock up the Z slide (Created page with "Chocking up the Z axis slide is necessary when the Z motor is going to be removed. The brake on the Z motor and the power of the Z motor when the machine is enabled are all that...") (current)
- 12:43, 6 September 2011 (diff | hist) . . (-1) . . Run away (→Scenario) (current)
- 12:41, 6 September 2011 (diff | hist) . . (+257) . . N Belt Tightness (Created page with "Proper belt tightness is key to proper running of an axis. An overtightened belt risks snapping a motor or ball screw shaft. An undertightened belt risks sloppy cuts Proper be...") (current)
- 12:39, 6 September 2011 (diff | hist) . . (+436) . . N Ball Screw End Bearings (Created page with "Ball screw end bearings are responsible for holding the ball screw in place both axially and whatever it is that orthogonal-to-axially is called. Overtightened ball screw end b...") (current)
- 12:37, 6 September 2011 (diff | hist) . . (+437) . . N Ball Nut Preload (Created page with "Ball nut preload is the amount of pressure the housing exerts on the mechanics (typically ball bearings)in a ball nut. Overtightening the preload on a ball nut will cause: * Pr...") (current)
- 12:33, 6 September 2011 (diff | hist) . . (+58) . . Touch-off problem (current)
- 12:32, 6 September 2011 (diff | hist) . . (+1) . . Troubleshooting (→Machine Doesn't Move)
- 12:31, 6 September 2011 (diff | hist) . . (+1) . . User:Efeldman (current)
- 12:29, 6 September 2011 (diff | hist) . . (+69) . . N User:Efeldman (Created page with "Eric Feldman Techno Design Engineer Mechanics, Software, Electronics")
- 12:27, 6 September 2011 (diff | hist) . . (+2) . . Command errors (current)
- 12:27, 6 September 2011 (diff | hist) . . (+12) . . m Command errors
- 12:27, 6 September 2011 (diff | hist) . . (+113) . . Command errors
- 12:25, 6 September 2011 (diff | hist) . . (+735) . . N Command errors (Created page with "Command errors are specific, infrequent communication errors between the Software and the PCI card. Identify your Controller box LC / LP controller box A command error on...")
- 12:20, 6 September 2011 (diff | hist) . . (+40) . . Troubleshooting (→Machine Doesn't Move)
- 12:15, 6 September 2011 (diff | hist) . . (+1,043) . . N Test the brake (Created page with "If a brake motor is getting very hot or suffering from position errors, it may be wise to test the brake. There are a few ways to test the brake. '''In a quiet environment, it...") (current)
- 12:08, 6 September 2011 (diff | hist) . . (+532) . . N Brake switch (Created page with "The brake switch disables the brake that holds the Z motor from falling when the machine is not powered. The brake switch on all modern systems is a 12mm/.5" round black momenta...") (current)
- 12:04, 6 September 2011 (diff | hist) . . (+21) . . Malformed gcode (current)
- 12:04, 6 September 2011 (diff | hist) . . (+344) . . N Malformed gcode (Created page with "G-Code for the Techno Router must be made to a certain specification. Posts are commonly made by CAM companies for each machine upon request. Techno posts exist for most major ...")
- 11:59, 6 September 2011 (diff | hist) . . (+134) . . N Multimeter (Created page with "This is a picture of a multimeter. Yours may look different, but the important symbols should be the same. File:Multimeter.jpg") (current)
- 11:59, 6 September 2011 (diff | hist) . . (+23) . . N File:Multimeter.jpg (Multimeter with symbols) (current)
- 11:50, 6 September 2011 (diff | hist) . . (+1,103) . . N Axis tightness (Created page with "In rare circumstances, one of the axes may suffer from tightness in only certain spots. To find this tightness, there is an axis lag test that can be run. This test is available...") (current)
- 11:50, 6 September 2011 (diff | hist) . . (+22) . . N File:Example lag.jpg (Example of lag results) (current)
- 11:39, 6 September 2011 (diff | hist) . . (+44) . . N File:Lag test.jpg (Machine test window after running a lag test) (current)
- 11:29, 6 September 2011 (diff | hist) . . (+172) . . Position Error (current)
- 11:27, 6 September 2011 (diff | hist) . . (+787) . . N Machine test (Created page with "The machine test runs all of the physical and electrical tests the machine can do in order to locate a problem. * Position the machine in the middle of travel for all axes. * ...") (current)
- 11:21, 6 September 2011 (diff | hist) . . (+320) . . N Loose mechanics (Created page with "Loose mechanics can be responsible for machine drift, poor cut quality and stuttering. There are several ways to isolate mechanical problems: * Run the machine Drift test ...") (current)
- 11:17, 6 September 2011 (diff | hist) . . (+633) . . N Encoder damage (Created page with "Encoders are sensors hooked up directly to servo motors. They monitor the position of the motor so the machine can position accurately. If there is damage to the encoder, it wi...") (current)
- 11:13, 6 September 2011 (diff | hist) . . (+51) . . Amplifier status (current)
- 11:13, 6 September 2011 (diff | hist) . . (+93) . . Amplifier status
- 11:12, 6 September 2011 (diff | hist) . . (+28) . . Amplifier status
- 11:12, 6 September 2011 (diff | hist) . . (+1,307) . . N Amplifier status (Created page with "It may be necessary to check to see if an amplifier is enabling. First, find your Controller box On the LC Plus control box: The amplifier status is read out on the badge...")
- 11:05, 6 September 2011 (diff | hist) . . (+1,394) . . N Set the origin (Created page with "Setting the origin For proper operation, the machine has to "match" up the coordinate system with that of the drawing that it is running. The origins are sometimes referred to...") (current)
- 10:58, 6 September 2011 (diff | hist) . . (+221) . . N Switch is smashed (Created page with "If the limit switch is suspected or determined to be smashed, it must be checked/replaced. Download and read the File:Replacing_a_limit_switch.pdf file. It contains all nec...") (current)